ZP-9A Series Automatic Rotary Tablet Press (ZP-5A/7A/9A)

The ZP-9A Series (including ZP-5A, ZP-7A, and ZP-9A) Automatic Rotary Tablet Press is a compact, high-speed pharmaceutical machine designed to continuously and automatically compress powder or granular raw materials into tablets. It is widely suitable for small-batch production and pilot-scale trial runs in pharmaceutical factories, health supplement plants, food and chemical industries, and scientific research laboratories. Its core advantages lie in delivering a powerful 50KN compression pressure within a compact footprint, achieving a maximum production capacity of 16,200 tablets/hour, and supporting both round and custom irregular-shaped tablets. The machine housing and all material-contact parts are constructed from high-quality stainless steel in full compliance with GMP hygiene standards, offering an ideal balance of cost-effectiveness and operational stability.
I. Product Overview & Core Advantages
The ZP-9A Series Automatic Rotary Tablet Press is specifically engineered to bridge the gap between the limited output of single-punch presses and the large footprint of heavy-duty high-speed rotary presses. It is an ideal choice for laboratory pilot production and continuous small-factory manufacturing. Its core advantages include:
- Multi-Station Configurations & Scalable Capacity: The series offers three punch-and-die configurations—5 stations (ZP-5A), 7 stations (ZP-7A), and 9 stations (ZP-9A)—covering maximum outputs from 9,000 pcs/h to 16,200 pcs/h, allowing users to select the exact model that matches their order volume.
- Strong Pressure & Irregular Tablet Compatibility: Delivering up to 50KN of tableting pressure, the machine easily compresses high-hardness powders and granular materials. In addition to standard round tablets up to 12mm in diameter, it supports custom tooling for irregular shapes up to 14mm, as well as embossed, debossed, or double-sided scored tablets.
- Compact Footprint & Flexible Deployment: Measuring just 480 × 630 × 1100 mm and weighing 180 kg, the machine requires minimal floor space and is easy to relocate. Its 1.5 KW motor ensures low energy consumption and quiet operation, making it ideal for space-constrained R&D laboratories and cleanrooms.
- Full Stainless Steel Protection & GMP Compliance: The compression chamber is enclosed with transparent plexiglass windows, providing clear visual monitoring of the tableting process while effectively preventing dust dispersion and cross-contamination. All core material-contact components are built from premium stainless steel for effortless disassembly, cleaning, and routine maintenance.
II. Core Technical Parameter Selection Table
To meet the needs of laboratories and small production workshops of varying scales, the core physical and operational parameters of the ZP-5A, ZP-7A, and ZP-9A standard models are compared below:
| Technical Parameter | ZP-5A | ZP-7A | ZP-9A |
|---|---|---|---|
| Number of Dies (Set) | 5 Sets | 7 Sets | 9 Sets |
| Max. Pressure | 50 KN | 50 KN | 50 KN |
| Max. Tablet Diameter | 12 mm (Irregular: 14 mm) | 12 mm (Irregular: 14 mm) | 12 mm (Irregular: 14 mm) |
| Max. Filling Depth | 15 mm | 15 mm | 15 mm |
| Max. Tablet Thickness | 6 mm | 6 mm | 6 mm |
| Turret Speed | 30 r/min | 30 r/min | 30 r/min |
| Production Capacity | 9,000 pcs/h | 12,600 pcs/h | 16,200 pcs/h |
| Motor Power | 1.5 KW | 1.5 KW | 1.5 KW |
| Dimension | 480 × 630 × 1100 mm | 480 × 630 × 1100 mm | 480 × 630 × 1100 mm |
| Machine Weight | 180 Kg | 180 Kg | 180 Kg |
(Note: The technical parameters above are manually measured and for reference only; actual specifications are subject to the delivered machine.)
III. Packaging & Shipping Information
For precision pharmaceutical and laboratory forming equipment, we provide comprehensive protection for factory dispatch and international delivery:
- MOQ & Sturdy Packaging: The minimum order quantity (MOQ) is 1 unit. Weighing 180 Kg, the machine undergoes moisture-proof and anti-rust treatment before being secured to a heavy-duty base and sealed in an export-standard fumigation-free fully enclosed plywood wooden case, ensuring absolute safety during sea or air freight.
- Factory Testing & Delivery: Upon order confirmation, standard models are promptly assembled and subjected to loaded trial runs. Each shipment includes a complete set of standard punches and dies, dedicated disassembly and maintenance tools, and bilingual (Chinese/English) operation manuals.
- After-Sales Warranty Policy: A one-year warranty covers the core motor, transmission system, and electrical components (excluding wearing parts such as punches and dies). For any non-human-induced mechanical failure during the warranty period, we provide free replacement parts and remote video technical guidance. Lifetime spare parts supply and technical support are available beyond the warranty period.
IV. Frequently Asked Questions (FAQ)
Q: What are the differences between the ZP-5A, ZP-7A, and ZP-9A models, and how should I choose? A: All three models share the exact same dimensions (480 × 630 × 1100 mm), weight (180 Kg), motor power (1.5 KW), and maximum tableting pressure (50 KN). The core difference is the number of punch-and-die stations mounted on the turret, which determines the hourly output: ZP-5A (5 stations) produces 9,000 pcs/h, ZP-7A (7 stations) produces 12,600 pcs/h, and ZP-9A (9 stations) reaches 16,200 pcs/h. If your budget allows and you want higher efficiency, we recommend choosing the highest-capacity ZP-9A directly.
Q: Can this compact rotary tablet press produce irregular-shaped tablets or tablets with custom logos? A: Yes. In addition to pressing standard round tablets up to 12mm in diameter, this series fully supports custom tooling to compress irregular shapes up to 14mm (such as ovals, triangles, and hearts) as well as custom tablets featuring brand lettering, logos, or break-line scores.
Q: What are the specific requirements for powder materials when compressing tablets? A: To ensure uniform filling and consistent tablet weight during continuous rotary compression at 30 r/min, raw powder materials should have good flowability and moderate moisture content. If fine powder has poor flowability or tends to stick to the punches, we recommend granulating it first (via dry or wet granulation) into uniform granules, or adding an appropriate amount of lubricant before tableting.